Set up communication with the instrument

Posted by on May 14, 2012 in Senza categoria | No Comments

HOW TO SET UP THE COMMUNICATION

to enable communication with the serial port 485 you must go to set 2 parameters, and exactly the address of the instrument, which will be 1 and the type of communication which will be 9600n: To do this we must do the following steps:

simultaneously press “▲” and “▼” to 3 seconds
press button “▲” appears until SYS
Click “OK”
press “▲” until you see Adr
Click “OK” button 3 seconds until the flashing
press “▲” or “▼” to bring up the parameter to 001
Click “OK”
press “▲” until you see CoM
Click “OK” button 3 seconds until the flashing
press “▲” or “▼” to bring the parameter of 96N

if the type of instrument so provides, you can plug a lamp or a ringtone x signal an alarm on the second contact, the extra buzzer PC
To do this we must set the parameter ALR = 0 with the following procedure.

simultaneously press “▲” and “▼” to 3/2
Press “▲” until you see ALr
Press “OK”
Press “▲” until ITS appears
Press “OK” button 3 seconds until the flashing
Press “▲” or “▼” to bring up the parameter to 000

to exit press the button “▼”

If you do not press any buttons for 40 seconds the instrument back to the temperature reading

now the instrument is ready to communicate.